Plage de mesure
Spectral Range: 250-410nm (covers UVA, UVB, UVC full spectrum)
Energy Range: 0-999999 mJ/cm²
Intensity Range: 0-9999 mW/cm²
Accuracy Indicators
Précision de mesure : ±5% (under standard conditions)
Repeatability: ±2%
Linearity: ±3%
Temperature Coefficient: ±0.1%/℃
Physical Parameters
Dimensions: Diameter 90mm × Thickness 12mm
Weight: Approximately 150g
Matériau du boîtier: Aluminum alloy/Stainless steel
Operating Temperature: -10℃ to 70℃
Power Parameters
Type d'alimentation : 3.6V lithium battery
Battery Life: Approximately 10000 hours
Power Consumption: 100μA (standby mode)
Charging Method: Dedicated charger
Mesureur d'énergie UV Instructions d'utilisation
Proper use of UV energy meters is key to ensuring measurement accuracy. Please follow these steps:
Mise sous tension Preparation
- Check if battery power is sufficient
- Ensure instrument surface is clean and contamination-free
- Confirm measurement environment temperature is within allowable range
- Check if the instrument has been calibrated
Measurement Operation
- Turn ON switch, LCD display shows zero
- Place UV energy meter near UV lamp source
- Ensure instrument back (sensor side) faces the light source
- Set appropriate exposure time according to process requirements
- Read measurement value on display screen
Precautions
- Do not look directly or indirectly at UV light source
- Avoid any body parts being directly exposed to UV light
- Instrument can withstand high temperatures, but not exceeding 10 seconds on conveyor belt
- Maximum temperature resistance 110℃, but recommended working temperature not exceeding 70℃
- Turn off power promptly after measurement
Enregistrement des données
- Record measurement date, time and ambient temperature
- Record UV lamp type and power
- Record measurement position and distance
- Perform regular data backup and analysis
- Establish measurement data archive
Mesureur d'énergie UV Étalonnage Methods
Regular calibration is key to ensuring UV energy meter measurement accuracy. We provide professional calibration services and method guidance.
Cycle d'étalonnage
Recommended Cycle d'étalonnage: 12 months
Frequent Use: 6 months
Critical Applications: 3 months
After Instrument Repair: Must be recalibrated
Normes d'étalonnage
Reference Standard: National metrology standards
Étalonnage Institutions: Authorized institutions like NIM
Certificat d'étalonnage : Provide authoritative calibration report
Traceability: Traceable to national standards
Étalonnage sur site
- Use standard UV light source for comparison
- Check instrument zero drift
- Verify measurement linearity
- Confirm temperature compensation function
- Record calibration data
Services d'étalonnage
- Provide on-site calibration services
- Mail-in calibration services
- Étalonnage certificate issuance
- Étalonnage data archiving
- Étalonnage cycle reminders
Mesureur d'énergie UV Entretien Guidelines
Proper maintenance can extend the service life of UV energy meters and ensure measurement accuracy.
Entretien quotidien
- Regularly clean instrument surface
- Check battery power
- Verify instrument functions properly
- Record usage conditions
- Store instrument properly
Entretien du capteur
- Avoid sensor contamination
- Regularly check sensor sensitivity
- Prevent mechanical damage to sensor
- Avoid direct strong light exposure to sensor
- Regular sensor calibration
Entretien de la batterie
- Regularly check battery voltage
- Avoid over-discharge
- Use original charger
- Remove battery when not in use for long periods
- Pay attention to battery replacement cycle
Troubleshooting
- Display not lit: Check battery
- Abnormal measurement values: Recalibrate
- Instrument not responding: Restart instrument
- Data loss: Check storage
- Other issues: Contact technical support
UV-int Energy Meter Model Comparison
According to different application requirements, we provide various models of UV energy meters for your selection.
UV-Int150
Mesureur d'énergie UV standard
Norme industrielleDesigned in 2004, standard measurement tool for UV curing industry
UV-Int140
Mesureur d'énergie UV + UV Light Warning
Conception innovanteSafety warning function, suitable for hazardous environments
UV-Int159
UV Energy + UV Intensity + Temperature Measurement
MultifonctionSuitable for multi-parameter measurement in complex process environments
UV-Int160
UV Energy + UV Intensity + Temperature + USB Connection
Haute performanceWith data recording and curve analysis functions
Professional Consultation technique
Professional Selection Guidance
If you are unsure which UV energy meter is most suitable for your production line or experimental needs, our technical team will provide professional selection advice and technical support.
Professional Support technique
Professional team provides UV testing solutions, technical consultation and after-sales service
View Catalogue complet des produitsUV-integrator
Designed & Manufactured by UV-int
Scan QR code to visit official website