Mesureur d'énergie UV Paramètres techniques

Understanding the technical parameters of UV energy meters is crucial for proper selection and use of the instrument. The following are detailed explanations of the main technical parameters.

Plage de mesure

Spectral Range: 250-410nm (covers UVA, UVB, UVC full spectrum)

Energy Range: 0-999999 mJ/cm²

Intensity Range: 0-9999 mW/cm²

Accuracy Indicators

Précision de mesure : ±5% (under standard conditions)

Repeatability: ±2%

Linearity: ±3%

Temperature Coefficient: ±0.1%/℃

Physical Parameters

Dimensions: Diameter 90mm × Thickness 12mm

Weight: Approximately 150g

Matériau du boîtier: Aluminum alloy/Stainless steel

Operating Temperature: -10℃ to 70℃

Power Parameters

Type d'alimentation : 3.6V lithium battery

Battery Life: Approximately 10000 hours

Power Consumption: 100μA (standby mode)

Charging Method: Dedicated charger

Mesureur d'énergie UV Instructions d'utilisation

Proper use of UV energy meters is key to ensuring measurement accuracy. Please follow these steps:

Mise sous tension Preparation

  • Check if battery power is sufficient
  • Ensure instrument surface is clean and contamination-free
  • Confirm measurement environment temperature is within allowable range
  • Check if the instrument has been calibrated

Measurement Operation

  • Turn ON switch, LCD display shows zero
  • Place UV energy meter near UV lamp source
  • Ensure instrument back (sensor side) faces the light source
  • Set appropriate exposure time according to process requirements
  • Read measurement value on display screen

Precautions

  • Do not look directly or indirectly at UV light source
  • Avoid any body parts being directly exposed to UV light
  • Instrument can withstand high temperatures, but not exceeding 10 seconds on conveyor belt
  • Maximum temperature resistance 110℃, but recommended working temperature not exceeding 70℃
  • Turn off power promptly after measurement

Enregistrement des données

  • Record measurement date, time and ambient temperature
  • Record UV lamp type and power
  • Record measurement position and distance
  • Perform regular data backup and analysis
  • Establish measurement data archive

Mesureur d'énergie UV Étalonnage Methods

Regular calibration is key to ensuring UV energy meter measurement accuracy. We provide professional calibration services and method guidance.

Cycle d'étalonnage

Recommended Cycle d'étalonnage: 12 months

Frequent Use: 6 months

Critical Applications: 3 months

After Instrument Repair: Must be recalibrated

Normes d'étalonnage

Reference Standard: National metrology standards

Étalonnage Institutions: Authorized institutions like NIM

Certificat d'étalonnage : Provide authoritative calibration report

Traceability: Traceable to national standards

Étalonnage sur site

  • Use standard UV light source for comparison
  • Check instrument zero drift
  • Verify measurement linearity
  • Confirm temperature compensation function
  • Record calibration data

Services d'étalonnage

  • Provide on-site calibration services
  • Mail-in calibration services
  • Étalonnage certificate issuance
  • Étalonnage data archiving
  • Étalonnage cycle reminders

Mesureur d'énergie UV Entretien Guidelines

Proper maintenance can extend the service life of UV energy meters and ensure measurement accuracy.

Entretien quotidien

  • Regularly clean instrument surface
  • Check battery power
  • Verify instrument functions properly
  • Record usage conditions
  • Store instrument properly

Entretien du capteur

  • Avoid sensor contamination
  • Regularly check sensor sensitivity
  • Prevent mechanical damage to sensor
  • Avoid direct strong light exposure to sensor
  • Regular sensor calibration

Entretien de la batterie

  • Regularly check battery voltage
  • Avoid over-discharge
  • Use original charger
  • Remove battery when not in use for long periods
  • Pay attention to battery replacement cycle

Troubleshooting

  • Display not lit: Check battery
  • Abnormal measurement values: Recalibrate
  • Instrument not responding: Restart instrument
  • Data loss: Check storage
  • Other issues: Contact technical support

UV-int Energy Meter Model Comparison

According to different application requirements, we provide various models of UV energy meters for your selection.

UV-Int150

Mesureur d'énergie UV standard

Norme industrielle

Designed in 2004, standard measurement tool for UV curing industry

UV-Int140

Mesureur d'énergie UV + UV Light Warning

Conception innovante

Safety warning function, suitable for hazardous environments

UV-Int159

UV Energy + UV Intensity + Temperature Measurement

Multifonction

Suitable for multi-parameter measurement in complex process environments

UV-Int160

UV Energy + UV Intensity + Temperature + USB Connection

Haute performance

With data recording and curve analysis functions

Professional Consultation technique

Professional Selection Guidance

If you are unsure which UV energy meter is most suitable for your production line or experimental needs, our technical team will provide professional selection advice and technical support.

Consultation en ligne View FAQ

Professional Support technique

+86 133 0651 2129

Professional team provides UV testing solutions, technical consultation and after-sales service

View Catalogue complet des produits